Chrome Labs monogramChrome LabsBuilt Different
Third-Party Verified

Certificate of AnalysisCertificate of Analysis

Independent third-party lab results for every compound we carry. View any report here, download the original PDF, and confirm it directly with the testing lab.

7 compounds, 9 reports
80 mg vial

KLOW blend

KPV, GHK-Cu, BPC-157, TB-500 (Thymosin Beta-4)

Blend purity
99.76%HPLC, all four components above 99.5%
Measured content
83.91 mgKPV 10.76, GHK-Cu 50.52, BPC-157 12.78, TB-500 9.85 mg
Endotoxin
Below LOQSpec ≤ 5 EU/mL, conforms
Lot
KL80-0926
  • Full certificate: identity, purity, quantity, endotoxinAccumark Labs · Sample ZZAD-Y6QX · Issued Sep 23, 2026
1,000 mg vial

NAD+

Purity
99.98%Mean of 2 vials
Measured content
1,101.64 mgMean of 2 vials, %RSD 0.49%
Endotoxin
PassSpec ≤ 5.0 EU/mL
Lot
NJ1000-0726
  • Full certificate: identity, purity, quantity, endotoxinAccumark Labs · Sample NFE8-3TE4 · Issued Sep 8, 2026
20 mg vial

Retatrutide

Purity
99.66–99.73%3 vials tested
Measured content
23.59–23.76 mg3 vials tested
Endotoxin
6.53 EU/vialAs reported by lab
  • HPLC purity and quantityJanoshik Analytical · Task #238160 · Issued Oct 2, 2026 · Verification key 1Y4GLBSCEEF4
  • Endotoxin analysisJanoshik Analytical · Task #238165 · Issued Oct 1, 2026 · Verification key XQN8BXF247JG
10 mg vial

Selank

Purity
99.97–99.98%3 vials tested
Measured content
12.38–12.59 mg3 vials tested
  • HPLC purity and quantityJanoshik Analytical · Task #238186 · Issued Oct 2, 2026 · Verification key CVZ7S3TAMQ5L
10 mg vial

Semax

Purity
99.25–99.38%3 vials tested
Measured content
10.35–10.92 mg3 vials tested
  • HPLC purity and quantityJanoshik Analytical · Task #238192 · Issued Oct 2, 2026 · Verification key ZQXM6FZW7R18
10 mg vial

Tesamorelin

Purity
99.81%HPLC
Measured content
12.91 mg
Endotoxin
PassSpec ≤ 5.0 EU/mL
Lot
TSM10-0728-01
  • Full certificate: identity, purity, quantity, endotoxinAccumark Labs · Sample U9ZQ-J4VC · Issued Sep 9, 2026
20 mg vial

Tirzepatide

Purity
99.84–99.86%3 vials tested
Measured content
23.02–23.54 mg3 vials tested
Endotoxin
1.38 EU/vialAs reported by lab
  • HPLC purity and quantityJanoshik Analytical · Task #238176 · Issued Oct 2, 2026 · Verification key U2ZPJYK18HZQ
  • Endotoxin analysisJanoshik Analytical · Task #238180 · Issued Oct 1, 2026 · Verification key 7KD41UZ9S9IH

Research use only

All compounds referenced are for research purposes only and are not for human or animal consumption.

Reports are published exactly as issued by the testing laboratory. Accumark Labs reports can be checked with the QR code on each certificate. Janoshik reports can be checked at janoshik.com/verify using the key listed with each report.